Pulse 3 HRV Sensor with Wireless

More Views

  • Pulse 3 Screen Rotation
  • Pulse 3 Screen Rotation-2
BCR PNPULSE3Biocomp Research Institute
PN Pulse 3 HRV Sensor with Wireless
$399.00

+ Free shipping USA & CAN (Restrictions Apply).

Add Items to Cart Add to Cart
Add to Wishlist Reviews

PN Pulse 3 HRV Sensor with wireless - PPG finger sensor for HRV, breath training, and standalone SPO2 monitoring.

The Pulse 3 has a very nice color LCD display for measuring SPO2 levels, complete with internal data recording and alarm settings, or it can connect via cable or wireless to PC software such as BioExplorer or BioEra for HRV training. Li battery recharged from a computer USB port.

Wireless range is greater than 25m, but note that only one wireless system can operate in a space. For operating multiple systems in the same space, use the USB cable provided.

The PN Pulse 3 PPG sensor can operate standalone with multi-color PPG trace, memory storage & SPO2 alarms when measuring SPO2 levels, or it can connect via cable or wireless to PC software such as BioExplorer or BioEra for HRV training.

Finger pulse oximeter Pulse 3 is a premium pulse oximeter loaded with features and is highly reliable and accurate. The pulse oximeter is designed for use at home and medical facilities, such as hospitals, doctor's offices, and medical centers. Pilots and athletes will find Pulse 3 helpful during their activities.

Pulse 3 can transfer real time data to your computer. Just turn on Bluetooth on your computer and Pulse 3 start the BioExplorer software (not included), and you will see your pulse and blood oxygen saturation level display on your computer monitor. This is an ideal way of capturing data for sleep apnea study or during exercise. Pulse 3 probe usage

The multicolor display of Pulse 3 is clear and attractive and is one of the best on the market. Pulse 3 has 4 display mode so the readings can be viewed from all directions. This makes the reading ease for the caretaker or the patient. The audible alarm can be configured and switched on/off as desired depending on the environment. Pulse 3 has an internal memory capable of storing 24-hour worth of data, which can be saved to a PC via a USB cable or Bluetooth adapter. Software is also included for reporting, data analysis and archive.

The pulse oximeter Pulse 3 comes with a rechargeable lithium ion battery that will last for up to 24 hours. The battery can be recharged via the USB port. You can use any USB power source (e.g. computer) or the included AC adapter.

The alarm is surprisingly loud for such a small device and can wake someone up unless you are a heavy sleeper. You can use this as a warning if the oxygen saturation level falls below a preset number or the pulse rate falls outside a given range.

A patient can record the data, print reports and show them to his doctor. This will further assist the doctor in evaluating the patient's condition. No more expensive equipment is required.

Features

  • Display SpO2 waveform (plethysmorgram), pulse rate, SPO2, pulse bar
  • Adjustable alarm thresholds
  • LCD display with four display modes
  • Bluetooth connection to PC
  • Reliable accuracy and durability
  • Automatic power-off design
  • Low power indicator
  • Pulse rate audio recognition function
  • Adjustable screen brightness
  • Real-time data transmission to computer
  • Software for data analysis and management
  • Storage for 24-hour data
  • USB cable and AC charger included
  • FDA 510(k)# K090671

Specifications

  • Display: 1.3" 65K Color OLED display
  • Screen Resolution: 128*96
  • SpO2:
    • Measurement range: 0-100%
    • Accuracy: 70-100% ±2%;
    • Resolution: 1%
  • Pulse rate:
    • Measurement range: 30-250 BPM
    • Accuracy: 30-100BPM ±2; 101-235BPM ±2%
    • Resolution: 1 BPM
  • Power Supply: 3.7v rechargeable lithium battery
  • Battery Working Hour: 20 hours
  • Battery working life: Charge and discharge no less than 500 times
  • Dimension: 57x32x30 mm
  • Weight: 50g including batteries
  • Automatic power-off after 5 seconds
  • Low power indicator
  • Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
  • Resistance to Surrounding Light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.

You may also be interested in the following product(s)

Pulse Oximeter

Pulse Oximeter
$675.00

Nonin 9843 Pulse Oximeter & CO2 Monitor

Nonin 9843 Pulse Oximeter & CO2 Monitor
$1,195.00

Nonin 9847 Pulse Oximeter & Carbon Dioxide Monitor w/alarms

Nonin 9847 Pulse Oximeter & Carbon Dioxide Monitor w/alarms
$1,295.00

PalmSAT 2500 Oximeter with Alarms

PalmSAT 2500 Oximeter with Alarms
$735.00