Skip to Store Area:

800.521.4640
Thought Technology MyoScan-Pro

More Views

  • SIde view of MyoscanPro with lead plugged in
  • Extender lead plugged in
  • Myoscan Pro v2 side view with lead plugged in
  • Detail of adjustable Filter Range switch
  • Back of MyoscanPro V2
  • Pins on Myoscan Sensor
TTL T9401M60Thought Technology
MyoScan-Pro v2 sEMG Sensor
$395.00

+ Free shipping USA & CAN (Restrictions Apply).

Add Items to Cart Add to Cart
Add to Wishlist Reviews

The Myoscan-Pro v2 (SA9401M-60) surface EMG sensor consists of 3 snap style receptacles - 2 active (positive & negative) and 1 reference (ground).

This EMG sensor kit (T9401M-60) is for use with Thought Technology ProComp Plus, ProComp Infiniti, ProComp 2, Procomp5, or Flexcomp series biofeedback and neurofeedback systems. Includes cable that connects the Sensor Head to the ProComp Infiniti encoder and snap lead cable. Operates in 60Hz environment.

  • MyoScan-Pro Sensor Head (SA9401M-60)
  • Approx. 48" (122.5cm)long connector cable to Encoder
  • Three Snap EMG Lead
  • Sample sEMG Sensors

The sEMG has a positive, a negative and a ground sensor. The signal is measured between the positive and negative. The ground acts as a reference point, and is used in filtering out electrical "noise" that is picked up from all three sensors.

Because some biofeedback sensors are applied directly to the skin or scalp, some consideration must be given to using proper hygienic controls. Whenever possible, we recommend the use of disposable sensors.

sEMG (Surface Electromyography) measures muscle activity by detecting and amplifying the tiny electrical impulses that are generated by muscle fibers when they contract. Since all the muscle fibers within the viewing and recording area of the sensor contract at different rates, the signal detected by the sensor is a constantly varying difference of potential between its positive and negative sensors. The number of muscle fibers that are recruited during any given contraction depends on the force required to perform the movement. Because of this, the intensity (amplitude) of the resulting electrical signal in proportional to the strength of contraction.

When placing the sEMG sensor on the muscle site, the best reading are obtained when the sensor is placed on the muscle belly and its positive and negative sensors are parallel to the muscle fibers. When using the extender cable, though, the direction of the fibers becomes irrelevant since the electrodes are frequently placed on different muscle groups. The positive and negative sensors should still be placed on the muscle bellies. The reference electrode is best placed on a relatively neutral site, like a bony prominence, preferably at an equal distance from the other two sensors.

  • Measurement unit: Raw signal in uV (Micro Volts)
  • Correlated data: RMS, peak, ratio, average, Power, dB, % Power depending on the system)
  • Accuracy: +/- 5%, +/- 0.3uV RMS
  • Sensor Input Impedance: 1,000,000 Meg Ohms in parallel with 10pF
  • Sensitivity: <0.1uV RMS
  • Bandwidth, switch selectable: 400W (Wide) = 20Hz - 500Hz, 400N (Narrow)= 100Hz - 200Hz, 1600W = 1600mV.
  • Input Range: 0-400uV RMS, 0 1600uV RMS
  • Size: 1.45" x 1.45" x 0.60" ( 37mm x 37mm x 15mm )
  • Weight: 1oz ( 25g)
Connection cable approx. 48 inches (122.5 cm) in length and plugs into a Thought Technology Encoder.