We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
This highly advanced dry EEG system that does not require paste, gel or extra wires. Bundled with Neuroguide Deluxe software allows for rapid QEEG acquisitions and analysis with Neuroguide.
DSI-Gold includes NeuroGuide Basic (Deluxe) (NG) that can import EEG from 45 different amplifiers with Normative Databases for linked ears, average reference, Laplacian and all Bipolar combinations from birth to 82 years of age and powerful analysis programs such as JTFA and FFT with the capability to add 15 different Add On products. Also includes the NeuroGuide Colleciton Module (NC) that is an add on to NeuroGuide to allow for the collection of EEG using the DSI-24.
The DSI-24 is a research grade wireless EEG headset designed for rapid application of 21 sensors at locations corresponding to the 10-20 International System.
The DSI-24's practicality, portability, and high signal quality opens the door to taking numerous applications that were previously limited to lab environments to more naturalistic settings. Such applications include:
NeuroGuide Basic (Deluxe) (NG) - Includes EEG imports from 45 different amplifiers, Normative Databases for linked ears, average reference, Laplacian and all Bipolar combinations and powerful analysis programs such as JTFA and FFT and capability to add 15 different add on products.
DSI-Streamer is Wearable Sensing's easy-to-use data acquisition software. The software features include:
Specifications |
DSI-24
|
DSI-7
|
Sensor Locations | 20 sensors at International 10/20 System locations: Fp1, Fp2, Fz, F3, F4, F7, F8, Cz, C3, C4, T3, T4, T5, T6, P3, P4, O1, O2, A1 and A2 |
7 sensors at the following International 10/20 System locations: F3, F4, C3, C4, Pz, P3, P4 + Linked Ear channel (2 earclip sensors) (Ask us about custom locations) |
Common-Mode-Follower |
Common Mode Follower sensor at Pz | Common Mode Follower Sensor at Pz |
Ground | One (1) ground electrode at Fpz | One (1) ground electrode at Fz |
Headset | Ideal for long-term ambulatory use in office or laboratory environment |
Ideal for ultra-rapid use in office or laboratory environment. |
Specifications |
DSI-24
|
Sensor Locations | Twenty (20) sensors at International 10/20 System locations: Fp1, Fp2, Fz, F3, F4, F7, F8, Cz, C3, C4, T3, T4, T5, T6, P3, P4, O1, O2, M1 and M2 |
Common-Mode-Follower |
One (1) Common Mode Follower sensor at Pz |
Ground | One (1) ground electrode at Fpz |
Headset | Easy to don, comfortable, and long-term wearable headset assembly with spring-loaded arms and pods for sensor support. Good for long-term ambulatory use in office or laboratory environment |
Amplifier/Digitizer |
One (1) 24-channel amplifier and digitizer |
Wireless | BlueTooth |
Run-time | Continuous (hot swappable) |
Headsize fit | 52-62cm circumference |
Headset weight | ~600g |
Wireless range: | 10m |
Digital Inputs: | 8 bit input |
Analog/Digital Converter: | 16 bits |
Analog/Digital resolution: | 0.317 uV referred to input |
Sample Rate: | 300 Hz |
Bandwidth: | 0.003-150Hz |
Gain: | 60 |
Common mode rejection ratio: | > 120dB |
Channel Cross-talk: | < -70dB with sensors |
Input Impedance (1Hz): | 47Gohm |
Input bias current: | <25pA |
DC offset tolerance: | +/-200mV |
Maximum input range: | 10mV pk-pk |
Noise (1-50Hz): | <3 uV pk-pk |