The Peak Performance System Packages are designed to include everything you'll need to cater to clients seeking to hone thier performance. Whether it be on the field or in the board room the Peak Performance Systems deliver results.
The Peak Performance 8 System Packages are a hassle free bundle that was carefully designed to set you up with everything you'll need to need to cater to your clients needs for high performance.
Silver - Gold - Platinum | |||
ProComp 8 Infiniti System | ✓ | ✓ | ✓ |
MyoScan-Pro v2 sEMG Sensor | x2 | x2 | x2 |
EEG-Z Impedance Sensor | ✓ | ✓ | |
Temperature Sensor | ✓ | ✓ | ✓ |
Respiration Sensor | ✓ | ✓ | ✓ |
Heart Rate/BVP Sensor | ✓ | ✓ | ✓ |
Skin Conductance Sensor | ✓ | ✓ | ✓ |
EKG Sensor | ✓ | ✓ | ✓ |
Peak Performance Suite for Infiniti | ✓ | ✓ | ✓ |
Cardio Pro Suite for Infiniti | ✓ | ✓ | ✓ |
BIOMAX Animation Pack | ✓ | ✓ | ✓ |
Reaction Time Suite for Infiniti | ✓ | ✓ | |
TT-AV Sync | ✓ | ✓ | |
Push Button Switch | x2 | x2 | |
Foot Pedal | ✓ | ✓ | |
Tele-Infiniti Compact Flash | ✓ | ✓ | |
Online Hourly Training | ✓ | x2 | |
GS03 Disposable sEMG Sensors (100) | ✓ | ||
GS27 Disposable sEMG Sensors (150) | ✓ | ||
NuPrep Skin Preparation Gel (3) | ✓ | ||
Ten20 Conductive Paste Tube (3) | ✓ | ||
Advanced Replacement 1 Year | ✓ | ||
Extended 2 Year Warranty | ✓ | ||
Automatic Loyalty Level 5 Discount | ✓ | ||
Regular Retail | $8099 | $11499 | $12699 |
Package Price | $7699 | $10399 | $10999 |
You Save | $400 | $1100 | $1700 |
The Procomp 8 device has 8 protected pin sensor inputs with two channels sampled at 2048 sampes per second and six channels sampled at 256 samples per second.
The ProComp Infiniti encoder is able to render a wide and comprehensive range of objective Physiological signs used in clinical observation and biofeedback.
The first two sensor channels of the Infiniti encoder provide ultimate signal fidelity (2048 samples per second) for viewing raw EEG, EMG and EKG signals. The remaining six channels (256 samples/sec) can be used with any combination of sensors, including EEG, EKG, RMS EMG, skin conductance, heart rate, blood volume pulse, respiration, goniometry, force, and voltage input.
ProComp Infiniti offers internal, user-activated calibration to ensure that you can always obtain the highest quality signal, without the costly downtime associated with factory re-calibration.
In short, the ProComp Infiniti covers the full range of objective physiological signals used in clinical observation and biofeedback.
Housed in an ergonomically designed case and requiring only a USB port, ProComp Infiniti can be used with any IBM-compatible laptop or desktop PC. Whats more, ProComp Infiniti can capture data in real time by connecting directly to the PC via fiber-optic cable, or it can store data on a Compact Flash memory card for uploading later to the PC.
The Infiniti software is created in a modular fashion to ensure you get only what you need and do not fill your computers memory with unwanted software. The Developer Tools will allow for high end users to create their own screens, scripts and channel sets. This ultimately provides the customer with the most variety under one system.
FlexComp Infiniti | ProComp Infiniti | ProComp5 | ProComp2 | |
Channels | 10 | 8 | 5 | 2 |
Compatible Sensors | EEG, SCP/EP, EMG, EKG, BVP(Blood Volume Pulse), Respiration, Temperature, Skin Conductance, Inclinometer, Algometer / Force, Bend, Foot Switch, Hand Push Button, Voltage Isolator, Force Adapter, Goniometer / Torsiometer Adapter, HEG | The same as FlexComp Infiniti | The same as FlexComp Infiniti | The same as FlexComp Infiniti |
Sensor Type | External sensors | External sensors | External sensors | 1 Internal EEG on Channel A. External sensors on B, C & D |
Impedance check (with EEG-Z sensor) |
All channels | All channels | All channels | Channel B only |
Sampling Rate | 2048 samples/sec on all 10 channels | 2048 samples/sec on Channel A and B, 256 samples/sec on Channel C, D, E, F, G, H |
2048 samples/sec on Channel A and B, 256 samples/sec on Channel C, D, E |
256 samples/sec on Channel A and B, 32 samples/sec on Channel C and D |
Connection to PC | Fiber Optic to USB through TT-USB interface unit. Or Compact Flash Module Bluetooth Tele-Infiniti | The same as FlexComp Infiniti | The same as FlexComp Infiniti | Fiber Optic to USB (TT-USB) or COM port (Pro-SB) or Tele-Infiniti |
Software and Suites | BioGraph Infiniti, Developer Tools, EEG Suite, Physiology Suite, and DynaMap Suite | BioGraph Infiniti, Developer Tools, either EEG Suite or Physiology Suite | The same as ProComp Infiniti | The same as ProComp Infiniti |
Weight | 200g (7oz) | 200g (7oz) | 200g (7oz) | 40 g (1.4oz) |
Size | 5.1" x 3.7" x 1.5" (130 mm x 95 mm x 37 mm) |
The same as FlexComp Infiniti | The same as FlexComp Infiniti | 2.2" x 2.8" x 0.75" (55 mm x 71 mm x19 mm) |
Self-calibration | Yes | Yes | Yes | No |
Compact Flash Memory Storage |
Yes | Yes | Yes | No |
Power Source | 4AA batteries, single-use alkaline or NiMH rechargeable | The same as FlexComp Infiniti | The same as FlexComp Infiniti | 1 AA battery, single-use alkaline or NiMH rechargeable |
Battery Life (alkaline) | 30 hours typical, 20 hours minimum | The same as FlexComp Infiniti | The same as FlexComp Infiniti | 10 hours typical |
*Some restrictions apply
View Computer Requirements for Thought Technology software (opens in a new browser tab)
General Requirements for Safety Compliant: UL60601-1 (R2003), CSA C22.2 601.1-M90 (R2005)
NOTE: ProComp Infiniti and its Sensor Heads and sensors are sensitive electronic instruments and should be handled as such. Be especially careful to avoid both pulling on the sensor cables and leads or getting moisture and gel on the sensor snaps. If necessary, wipe the surface with a damp cloth or use a moistened Q-tip to remove gel from inside the sensor snaps. Wipe with a dry cloth.