Sign In for Free Shipping on USA orders $100+ and CAN orders $200+
Office closed Thursday & Friday. We'll be back Monday, Dec 1

Elefix V Conductive EEG and EMG Paste - 180 g Tube

  • New and improved formula to keep electrodes directly on skin
  • Improved resistance to perspiration and high temperatures
  • pH neutral. Low impedance. Highly conductive
  • Can be used with all surface applied electrodes
Our Part #
NIK ELEFIX-V
Manufacturer Part #
ZV-181E10

In Stock
was $19.99 Special Price $17.99
  • Buy 10 for $17.79 each and save 1%
  • Buy 50 for $16.79 each and save 7%
Order in these convenient amounts
10 per box
50 per case

Elefix V EEG electrode paste is low impedance, highly conductive, and specially formulated to stick the electrodes on skin without additional adhesive disks.

Elefix Key Benefits

  • Lowers skin/electrode impedance to support stable EEG/EMG recordings.
  • Holds surface electrodes in place without extra adhesive disks.
  • Water-based with sodium chloride as the conductive material; remains pliable and conductive during recordings.
  • Not GHS-classified as hazardous under the SDS; intended for external use only.

When to Use

Use Elefix when you need reliable, low-impedance contact between surface electrodes and skin. It's ideal wherever a viscous, stay-put conductive medium helps stabilize signals and keep electrodes in place.

  • Routine scalp EEG and long-term EEG where low impedance and reliable adhesion are needed.
  • Surface EMG exams using cup/disc electrodes.
  • As the conductive medium under cup electrodes (place paste in the cup, apply, then secure per facility protocol).

Application Instructions

  1. Prep the skin per facility policy (clean and dry; apply skin-prep only if indicated). Follow your equipment manual.
  2. For cup electrodes: place a small amount of Elefix in the cup, apply to the skin, then secure the lead per protocol.
  3. Check impedances and signal quality; re-seat any sites showing poor contact.
  4. Do not reuse paste; close the cap after each use.

Clean Up

  • From skin: wipe away with water or lukewarm water; wash hands thoroughly after use.
  • From electrodes/leads: remove residual paste promptly; avoid abrasive cleaners (e.g., steel wool).
  • Solubility note: all components except calcium carbonate dissolve in water, aiding clean-up.

Ingredients

Water; Polyoxyethylene oleyl ether; PEG-60 Hydrogenated Castor Oil; Calcium Carbonate; Petrolatum; Glycerin; Sodium Chloride; Propylene Glycol; PEG-40 Hydrogenated Castor Oil; Cetyl Alcohol; BHT (<0.1%); Methylparaben (<0.1%); Propylparaben.

Safety Information

  • External use only. Do not apply to wounds, rashes, inflamed or infected skin, or skin eruptions. Discontinue if irritation appears.
  • If contact occurs with eyes or mouth, rinse thoroughly with water and seek medical advice if needed; if swallowed, see a physician.
  • Not classified as hazardous per GHS; handle by trained personnel and follow the operator’s manual.
  • For use with external electrodes by qualified personnel within a medical facility.

Storage and Handling

  • Store in a well-ventilated, dark place; avoid direct sunlight and high temperatures; keep out of reach of children.
  • Use before expiration; use up as soon as possible after opening; close the cap each time.
  • Follow local regulations for disposal; if potentially contaminated, dispose as medical waste.