Nihon Kohden skinPure EEG & ECG Skin Prep Gel - 2 pack of 4 oz tubes

  • Fast prep lowers impedance for clearer EEG/ECG signals
  • Stable contact helps reduce artifacts in routine and ambulatory monitoring
  • Gentle on intact adult skin with minimal mechanical abrasion
  • Water-removable, low-odor paste for easy cleanup and patient comfort
Our Part #
NIK SKINPURE
Manufacturer Part #
YZ-0019

In Stock
$38.99
Order in these convenient amounts
5 per box

SkinPure is a fast, water-removable prep that lowers impedance for cleaner EEG and ECG signals. It improves electrode contact, reduces artifacts, and speeds setup for routine exams and busy labs. 2 pack of 4 ounce tubes

SkinPure Key Benefits

  • Stable contact and cleaner signals helps maintain electrode contact and produce clearer waveforms
  • Lower impedance reduces skin–electrode impedance for enhanced EEG/ECG quality
  • Fewer motion artifacts useful in settings where movement can distort readings
  • Easy to work with white, low-odor paste that is water-removable with all components except sea sand dissolving in water

When to Use

Use Nihon Kohden skinPure for fast, reliable prep that helps electrodes stay put and signals stay clean.

  • Routine EEG and qEEG quick prep lowers impedance and baseline noise for clearer tracings.
  • Long-term and ambulatory rub-in stays stable longer, reducing artifacts and re-prep.
  • ECG lead placement improved contact supports consistent R-wave detection.
  • High-motion settings better contact helps during movement and sleep studies.
  • Busy clinics and labs rub-on, wipe-off workflow speeds room turnover.
  • Sensitive use cases gentler mechanical prep on intact adult skin when abrasives are undesirable.

Application Instructions

  1. Clean and dry the site per facility protocol.
  2. Apply a small amount of skinPure to the site and gently rub to prepare the skin surface.
  3. Wipe away excess gel and allow the area to dry.
  4. Apply electrodes and verify impedances per your device's instructions.

Clean Up

  • From skin: wipe away with water or lukewarm water; wash hands thoroughly after use.
  • From equipment: remove residue with a soft, damp cloth; avoid abrasive pads or solvents that could damage electrode surfaces.
  • If spilled: product can be slippery; absorb and mop with water.

Ingredients

Water; Sea sand; Propylene glycol; Potassium oleate; Carboxyvinylpolymer; Sodium hydroxide (neutralized with carboxyvinylpolymer); p-Chloro-m-xylenol; Methyl parahydroxybenzoate (methylparaben); Disodium EDTA.

Safety Information

  • For external use only. Do not rub the skin too hard—over-abrading may inflame skin.
  • If rash, itch, swelling, or other abnormality appears, wash off immediately and discontinue use.
  • Avoid contact with eyes or mouth; rinse with plenty of water if contact occurs and seek medical advice if needed. If swallowed and unwell, consult a physician.
  • Do not use past the stated lifetime. Keep out of reach of patients and children.
  • Not classified as hazardous under GHS; handle by trained personnel.

Storage and Handling

  • Store capped in a cool, well-ventilated, dark place away from direct sunlight.
  • Close the cap each time; if left uncapped, the gel may dry and lose its ability to lower contact impedance.
  • Use up as soon as possible after opening; do not use expired product.
  • Dispose of any remainder and packaging in accordance with local regulations.