The ProComp Infiniti System Packages are designed to include everything you'll need to cater to all of your clients needs. Hassle and worry are not included with this system.
The ProComp 8 System Packages are hassle-free bundles, carefully designed to set you up with everything you'll need to need to cater to any of your clients' needs.
Silver - Gold - Platinum |
ProComp 8 Infiniti System |
✓ |
✓ |
✓ |
360 Suite for Infiniti |
✓ |
✓ |
✓ |
EMG Sensor for FlexComp/Myotrac |
x2 |
x2 |
x2 |
EEG-Z Impedance Sensor |
|
x2 |
x2 |
Temperature Sensor |
✓ |
✓ |
✓ |
Respiration Sensor |
x2 |
✓ |
✓ |
Heart Rate/BVP Sensor |
✓ |
✓ |
✓ |
Skin Conductance Sensor |
✓ |
✓ |
✓ |
Online Hourly Training |
✓ |
✓ |
x2 |
BIOMAX Animation Pack |
|
✓ |
✓ |
GS03 Disposable sEMG Sensors (100) |
✓ |
|
✓ |
GS27 Disposable sEMG Sensors (150) |
✓ |
|
✓ |
NuPrep Skin Preparation Gel (3) |
|
|
✓ |
Ten20 Conductive Paste Tube (3) |
|
|
✓ |
Advanced Replacement 1 Year |
|
|
✓ |
Extended 2 Year Warranty |
|
|
✓ |
Automatic Loyalty Level 5 Discount |
|
|
✓ |
Regular Retail |
$7699 |
$8599 |
$9699 |
Package Price |
$6999 |
$7999 |
$8199 |
You Save |
$700 |
$600 |
$1500 |
ProComp Infiniti Hardware
The ProComp Infiniti encoder is able to render a wide and comprehensive range of objective physiological signals used in clinical observation and biofeedback.
The ProComp Infiniti has eight protected pin sensor inputs with two channels sampled at 2048 samples per second, and six channels sampled at 256 samples per second.
The first two sensor channels of the ProComp Infiniti encoder provide ultimate signal fidelity for viewing raw EEG, EMG and EKG signals (2048 samples per second). The remaining six channels can be used with any combination of sensors, including EEG, EKG, RMS EMG, skin conductance, heart rate, blood volume pulse, respiration, goniometry, force, and voltage input (256 samples/sec).
ProComp Infiniti offers internal, user-activated calibration to ensure that you can always obtain the highest quality signal, without the costly downtime associated with factory re-calibration.
Housed in an ergonomically designed case and requiring only a USB port, ProComp Infiniti can be used with any PC desktop or notebook.
ProComp Infiniti can capture data in real time by connecting directly to the PC via fiber-optic cable, or it can store data on a Compact Flash memory card for uploading later to the PC.
ProComp Encoder Comparison
|
FlexComp Infiniti |
ProComp Infiniti |
ProComp5 |
ProComp2 |
Channels |
10 |
8 |
5 |
2 |
Compatible Sensors |
EEG, SCP/EP, EMG, EKG, BVP(Blood Volume Pulse), Respiration, Temperature, Skin Conductance, Inclinometer, Algometer / Force, Bend, Foot Switch, Hand Push Button, Voltage Isolator, Force Adapter, Goniometer / Torsiometer Adapter, HEG |
The same as FlexComp Infiniti |
The same as FlexComp Infiniti |
The same as FlexComp Infiniti |
Sensor Type |
External sensors |
External sensors |
External sensors |
1 Internal EEG on Channel A. External sensors on B, C & D |
Impedance check
(with EEG-Z sensor) |
All channels |
All channels |
All channels |
Channel B only |
Sampling Rate |
2048 samples/sec on all 10 channels |
2048 samples/sec
on Channel A and B,
256 samples/sec
on Channel C, D, E, F, G, H |
2048 samples/sec
on Channel A and B,
256 samples/sec
on Channel C, D, E |
256 samples/sec
on Channel A and B,
32 samples/sec
on Channel C and D |
Connection to PC |
Fiber Optic to USB through TT-USB interface unit. Or Compact Flash Module Bluetooth Tele-Infiniti |
The same as FlexComp Infiniti |
The same as FlexComp Infiniti |
Fiber Optic to USB (TT-USB) or COM port (Pro-SB) or Tele-Infiniti |
Software and Suites |
BioGraph Infiniti, Developer Tools, EEG Suite, Physiology Suite, and DynaMap Suite |
BioGraph Infiniti, Developer Tools, either EEG Suite or Physiology Suite |
The same as ProComp Infiniti |
The same as ProComp Infiniti |
Weight |
200g (7oz) |
200g (7oz) |
200g (7oz) |
40 g (1.4oz) |
Size |
5.1" x 3.7" x 1.5"
(130 mm x 95 mm x 37 mm) |
The same as FlexComp Infiniti |
The same as FlexComp Infiniti |
2.2" x 2.8" x 0.75"
(55 mm x 71 mm x19 mm) |
Self-calibration |
Yes |
Yes |
Yes |
No |
Compact Flash
Memory Storage |
Yes |
Yes |
Yes |
No |
Power Source |
4AA batteries, single-use alkaline or NiMH rechargeable |
The same as FlexComp Infiniti |
The same as FlexComp Infiniti |
1 AA battery, single-use alkaline or NiMH rechargeable |
Battery Life (alkaline) |
30 hours typical, 20 hours minimum |
The same as FlexComp Infiniti |
The same as FlexComp Infiniti |
10 hours typical |
ProComp Infiniti Hardware Quick Start & User's Guide
360 Suite User Manual
Procomp Infiniti Hardware Manual
System Requirements
View Computer Requirements for Thought Technology software (opens in a new browser tab)
Specifications
HARDWARE FEATURES
- USB connection
- Internal user-activated recalibration
- Ability to save directly to Compact Flash Memory Card
- Integrated impedence checking
- High Sampling rate
- Automatic sensor recognition
- Ergonomic design
- Easily accessible dip switches
- Recessed fiber optic plug
- One-year warranty
SOFTWARE FEATURES
- Realtime frequency analysis
- User programmable waveform arithmetic, statistics/DSP
- Fast 3D spectral arrays
- Software filters to export data to Microsoft Excel for further calculations
- Realtime events and markers.
HARDWARE SPECIFICATIONS
- 15 Foot Fiber Optic Cable to USB (TT-USB interface) or COM port(Pro-SB)
- Impedance check (with optional EEG-Z sensor)
- Self-calibration: Yes
- Fast Channels: 2 channels, 2048 samples/sec DC-45Hz
- Slow channels: 5 channels 256 samples/sec DC-8Hz (shared with fast channels)
- Power Source: 4 1.5V AA Battery (20+ hours)
- Size (approx.) 130mm x 95mm x 37mm (5.1 x 3.7 x 1.5)
- Weight (approx.) 200g (7oz)
- Power Source 4AA batteries, single use alkaline or NiMh Rechargeable
- Supply Voltage 3.6V 6.5V (fiber optic), minimum 4.0V (Compact Flash)
- Battery Life, Alkaline cells 30h typical, 20h minimum
- Low-battery warning 20 30 minutes of battery life remaining
- Sensor supply voltage 7.260V 2mV
- ADC output 14bits
- Full-scale input range, DC 2.8V1.696V
- LSB magnitude 207uV
- Encoder channel bandwidth (3dB) and sample rate
- DC 512Hz @ 2048 samples/second
- DC 64Hz @ 256 samples/second
- DC 64Hz @ 200 samples/second
- DC 8Hz @ 32 samples/second
- DC 8Hz @ 20 samples/second
- Anti-aliasing Filter 5th order Butterworth
- Alias rejection 30dB typical
- DC gain accuracy 0.5% (initial, or after self-calibration)
- DC offset 3LSB (initial, or after self-calibration)
- Overall system accuracy 5%
- Offset drift, calibration temperature 10C 5 LSB
- Encoder noise 150uV RMS, 1mV p-p typical, offset removed
General Requirements for Safety Compliant: UL60601-1 (R2003), CSA C22.2 601.1-M90 (R2005)
ProComp Infiniti and its Sensor Heads and sensors are sensitive electronic instruments and should be handled as such. Be careful to avoid pulling on the sensor cables and leads, or getting moisture and gel on the sensor snaps. If necessary, wipe the surface with a damp cloth or use a moistened Q-tip to remove gel from inside the sensor snaps, then wipe dry.