ProComp Infiniti System Packages

  • Built to handle most clinical use cases without extra setup
  • Powerful, versatile 8 channel Infiniti encoder
  • Include training, supplies, custom screens and more
  • Extended tech support, advanced hardware replacement
Our Part #
TTL T7520M-S

In Stock
Only %1 left
As low as $6,999.00 was $7,699.00

Put together for real-world use, these packages include the core components needed to get started without the usual trial and error, so you can spend less time assembling and more time delivering effective training and results.

Complete 8-Channel Biofeedback & Neurofeedback System

Comprehensive system package includes ProComp hardware, BioGraph Infiniti software, and essential sensors for EEG, EMG, HRV, respiration, and temperature training.

Integrated BioGraph Infiniti Platform

Supports real-time data acquisition, customizable training screens, and advanced multimodal protocols for both biofeedback and neurofeedback applications.

High-Resolution, Clinical-Grade Performance

24-bit data acquisition, optical isolation, and modular sensor compatibility ensure accurate, reliable signals for clinical, research, and performance settings.

The ProComp 8 System Packages are hassle-free bundles, carefully designed to set you up with everything you'll need to need to cater to any of your clients' needs.

Silver Gold Platinum
ProComp 8 Infiniti System
360 Suite for Infiniti
EMG Sensor for FlexComp/Myotracx2x2x2
EEG-Z Impedance Sensorx2x2
Temperature Sensor
Respiration Sensorx2
Heart Rate/BVP Sensor
Skin Conductance Sensor
Online Hourly Trainingx2
BIOMAX Animation Pack
GS03 Disposable sEMG Sensors (100)
GS27 Disposable sEMG Sensors (150)
NuPrep Skin Preparation Gel (3)
Ten20 Conductive Paste Tube (3)
Advanced Replacement 1 Year
Extended 2 Year Warranty
Automatic Loyalty Level 5 Discount
Regular Retail$7,699$9,199$10,299
Package Price$6,999$8,799$8,999
Total Savings$700$400$1,300

Platinum Package

  • A complete set of biofeedback & neurofeedback sensors, ensuring that you'll never be without the right tool
  • Two hours of online training to aide you in becoming proficient with the system and software
  • Two years of extended tech support, available to assist you with any concerns
  • Advance replacement in the event of equipment failure, minimizing downtime
  • Custom built screen add-ons only available from bio-medical
  • 10% discount on all future purchases!*
  • Procomp Infiniti 8 Channel Encoder
  • Biofeedback Sensors & Neurofeedback Sensors include:
    • (2) Myoscan-Pro sEMG Sensors
    • (2) EEG-Z Sensors w/built in Impedance
    • (1) Temperature Sensor
    • (1) Respiration Sensor
    • (1) Heart Rate/BVP Sensor
    • (1) Skin Conductance Sensor
  • Software
    • Biograph Infiniti
    • 360 Suite
    • BIOMAX Animation Pack
    • Developer Tools
  • Supplies
    • DS03 Round foam Disposable sEMG Sensors (100pk)
    • GS27 Disposable Electrodes (150pk)
    • NuPrep Skin prep gel (3pk)
    • Ten20 Conductive paste (3pk)
  • 2 Hours of Personalized Online Training
  • Advanced Replacement for 1 year
  • Extended 2 Year Warranty
  • 14 bit resolution, eight-channel ProComp Infiniti encoder unit
  • TT-USB interface unit
  • Fiber-optic cables (12 inch & 15 foot)
  • Four alkaline AA batteries
  • Sleek fabric storage and carrying case


Gold Package

  • A complete set of biofeedback & neurofeedback sensors, ensuring that you'll never be without the right tool
  • One hour of online training to aide you in becoming proficient with the system and software
  • Custom built screen add-ons only available from bio-medical
  • Procomp Infiniti 8 Channel Encoder
  • Biofeedback Sensors & Neurofeedback Sensors include:
    • (2) Myoscan-Pro sEMG Sensors
    • (2) EEG-Z Sensors w/built in Impedance
    • (1) Temperature Sensor
    • (1) Respiration Sensor
    • (1) Heart Rate/BVP Sensor
    • (1) Skin Conductance Sensor
  • Software
    • Biograph Infiniti
    • 360 Suite
    • BIOMAX Animation Pack
    • Developer Tools
  • 1 Hours of Personalized Online Training
  • 14 bit resolution, eight-channel ProComp Infiniti encoder unit
  • TT-USB interface unit
  • Fiber-optic cables (12 inch & 15 foot)
  • Four alkaline AA batteries
  • Sleek fabric storage and carrying case


Silver Package

  • A complete set of biofeedback & neurofeedback sensors, ensuring that you'll never be without the right tool
  • Custom built screen add-ons only available from bio-medical
  • Procomp Infiniti 8 Channel Encoder
  • Biofeedback Sensors & Neurofeedback Sensors include:
    • (2) Myoscan-Pro sEMG Sensors
    • (1) Temperature Sensor
    • (2) Respiration Sensor
    • (1) Heart Rate/BVP Sensor
    • (1) Skin Conductance Sensor
  • Software
    • Biograph Infiniti
    • 360 Suite
    • BIOMAX Animation Pack
    • Developer Tools
  • Supplies
    • DS03 Round foam Disposable sEMG Sensors (100pk)
    • GS27 Disposable Electrodes (150pk)
  • 14 bit resolution, eight-channel ProComp Infiniti encoder unit
  • TT-USB interface unit
  • Fiber-optic cables (12 inch & 15 foot)
  • Four alkaline AA batteries
  • Sleek fabric storage and carrying case

*Some restrictions apply

Write Your Own Review
You're reviewing:ProComp Infiniti System Packages
Your Rating

Platinum Package

  • A complete set of biofeedback & neurofeedback sensors, ensuring that you'll never be without the right tool
  • Two hours of online training to aide you in becoming proficient with the system and software
  • Two years of extended tech support, available to assist you with any concerns
  • Advance replacement in the event of equipment failure, minimizing downtime
  • Custom built screen add-ons only available from bio-medical
  • 10% discount on all future purchases!*
  • Procomp Infiniti 8 Channel Encoder
  • Biofeedback Sensors & Neurofeedback Sensors include:
    • (2) Myoscan-Pro sEMG Sensors
    • (2) EEG-Z Sensors w/built in Impedance
    • (1) Temperature Sensor
    • (1) Respiration Sensor
    • (1) Heart Rate/BVP Sensor
    • (1) Skin Conductance Sensor
  • Software
    • Biograph Infiniti
    • 360 Suite
    • BIOMAX Animation Pack
    • Developer Tools
  • Supplies
    • DS03 Round foam Disposable sEMG Sensors (100pk)
    • GS27 Disposable Electrodes (150pk)
    • NuPrep Skin prep gel (3pk)
    • Ten20 Conductive paste (3pk)
  • 2 Hours of Personalized Online Training
  • Advanced Replacement for 1 year
  • Extended 2 Year Warranty
  • 14 bit resolution, eight-channel ProComp Infiniti encoder unit
  • TT-USB interface unit
  • Fiber-optic cables (12 inch & 15 foot)
  • Four alkaline AA batteries
  • Sleek fabric storage and carrying case


Gold Package

  • A complete set of biofeedback & neurofeedback sensors, ensuring that you'll never be without the right tool
  • One hour of online training to aide you in becoming proficient with the system and software
  • Custom built screen add-ons only available from bio-medical
  • Procomp Infiniti 8 Channel Encoder
  • Biofeedback Sensors & Neurofeedback Sensors include:
    • (2) Myoscan-Pro sEMG Sensors
    • (2) EEG-Z Sensors w/built in Impedance
    • (1) Temperature Sensor
    • (1) Respiration Sensor
    • (1) Heart Rate/BVP Sensor
    • (1) Skin Conductance Sensor
  • Software
    • Biograph Infiniti
    • 360 Suite
    • BIOMAX Animation Pack
    • Developer Tools
  • 1 Hours of Personalized Online Training
  • 14 bit resolution, eight-channel ProComp Infiniti encoder unit
  • TT-USB interface unit
  • Fiber-optic cables (12 inch & 15 foot)
  • Four alkaline AA batteries
  • Sleek fabric storage and carrying case


Silver Package

  • A complete set of biofeedback & neurofeedback sensors, ensuring that you'll never be without the right tool
  • Custom built screen add-ons only available from bio-medical
  • Procomp Infiniti 8 Channel Encoder
  • Biofeedback Sensors & Neurofeedback Sensors include:
    • (2) Myoscan-Pro sEMG Sensors
    • (1) Temperature Sensor
    • (2) Respiration Sensor
    • (1) Heart Rate/BVP Sensor
    • (1) Skin Conductance Sensor
  • Software
    • Biograph Infiniti
    • 360 Suite
    • BIOMAX Animation Pack
    • Developer Tools
  • Supplies
    • DS03 Round foam Disposable sEMG Sensors (100pk)
    • GS27 Disposable Electrodes (150pk)
  • 14 bit resolution, eight-channel ProComp Infiniti encoder unit
  • TT-USB interface unit
  • Fiber-optic cables (12 inch & 15 foot)
  • Four alkaline AA batteries
  • Sleek fabric storage and carrying case

*Some restrictions apply

ProComp Infiniti Hardware Quick Start & User's Guide

360 Suite User Manual

Procomp Infiniti Hardware Manual

System Requirements

View Computer Requirements for Thought Technology software (opens in a new browser tab)

Specifications

HARDWARE FEATURES
  • USB connection
  • Internal user-activated recalibration
  • Ability to save directly to Compact Flash Memory Card
  • Integrated impedence checking
  • High Sampling rate
  • Automatic sensor recognition
  • Ergonomic design
  • Easily accessible dip switches
  • Recessed fiber optic plug
  • One-year warranty
SOFTWARE FEATURES
  • Realtime frequency analysis
  • User programmable waveform arithmetic, statistics/DSP
  • Fast 3D spectral arrays
  • Software filters to export data to Microsoft Excel for further calculations
  • Realtime events and markers.
HARDWARE SPECIFICATIONS
  • 15 Foot Fiber Optic Cable to USB (TT-USB interface) or COM port(Pro-SB)
  • Impedance check (with optional EEG-Z sensor)
  • Self-calibration: Yes
  • Fast Channels: 2 channels, 2048 samples/sec DC-45Hz
  • Slow channels: 5 channels 256 samples/sec DC-8Hz (shared with fast channels)
  • Power Source: 4 1.5V AA Battery (20+ hours)
  • Size (approx.) 130mm x 95mm x 37mm (5.1 x 3.7 x 1.5)
  • Weight (approx.) 200g (7oz)
  • Power Source 4AA batteries, single use alkaline or NiMh Rechargeable
  • Supply Voltage 3.6V 6.5V (fiber optic), minimum 4.0V (Compact Flash)
  • Battery Life, Alkaline cells 30h typical, 20h minimum
  • Low-battery warning 20 30 minutes of battery life remaining
  • Sensor supply voltage 7.260V 2mV
  • ADC output 14bits
  • Full-scale input range, DC 2.8V1.696V
  • LSB magnitude 207uV
  • Encoder channel bandwidth (3dB) and sample rate
    • DC 512Hz @ 2048 samples/second
    • DC 64Hz @ 256 samples/second
    • DC 64Hz @ 200 samples/second
    • DC 8Hz @ 32 samples/second
    • DC 8Hz @ 20 samples/second
  • Anti-aliasing Filter 5th order Butterworth
  • Alias rejection 30dB typical
  • DC gain accuracy 0.5% (initial, or after self-calibration)
  • DC offset 3LSB (initial, or after self-calibration)
  • Overall system accuracy 5%
  • Offset drift, calibration temperature 10C 5 LSB
  • Encoder noise 150uV RMS, 1mV p-p typical, offset removed

General Requirements for Safety Compliant: UL60601-1 (R2003), CSA C22.2 601.1-M90 (R2005)

ProComp Infiniti and its Sensor Heads and sensors are sensitive electronic instruments and should be handled as such. Be careful to avoid pulling on the sensor cables and leads, or getting moisture and gel on the sensor snaps. If necessary, wipe the surface with a damp cloth or use a moistened Q-tip to remove gel from inside the sensor snaps, then wipe dry.

We found other products you might like!